| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
We report a venous oxygen embolism that occurred in a 66-yr-old man after 60 mL of 3% hydrogen peroxide was injected into a perianal fistula intraoperatively to locate its internal opening. The diagnosis was made after detecting hypoxemia, decreased end-tidal carbon dioxide tension, systemic hypotension, increased central venous pressure, and a new heart murmur. The patient recovered quickly and had no long-term sequelae. Oxygen embolism is a potentially fatal complication that can develop when hydrogen peroxide is used near venous spaces, and clinicians should be aware of the potential dangers when using this seemingly innocuous chemical. IMPLICATIONS: Hydrogen peroxide is used intraoperatively and perioperatively for the identification of fistula tracts. A venous oxygen embolism occurred in a 66-yr-old man after the intraoperative injection of 60 mL 3% hydrogen peroxide into an enterocutaneous fistula. The relevant aspects of the diagnosis and treatment of oxygen embolism are discussed.
Hydrogen peroxide (H2O2) is an oxidizing chemical frequently used during surgery for wound irrigation and cleansing. In the presence of the ubiquitous enzyme catalase, H2O2 quickly decomposes to water and oxygen in the following manner: 2H2O2 2H2O + O2 (1). At standard temperature and pressure, each mL of 3% H2O2 elaborates almost 10 mL of O2 (2). Surgeons have exploited the effervescent release of O2 to locate the internal opening of enterocutaneous fistula tracts because when H2O2 is injected into the visible external opening of the fistula, O2 bubbles percolate through the fistula tract and can be observed at the origin of the internal opening (3,4). In recent years, H2O2 has been endorsed as a contrast medium for the ultrasonographic assessment of perianal disease including fistula-in-ano and anovaginal fistulae (5,6). However, the O2 produced from H2O2 can cause significant morbidity and mortality when it has access to the venous circulation (713). Therefore, its routine use for fistula identification surgically or ultrasonographically may be unwise. We present the first case of oxygen embolism associated with the intraoperative injection of H2O2 to identify the internal opening of a fistula tract.
A 66-yr-old, 50-kg man was admitted with a Crohns disease exacerbation. He had complex perianal disease that had been surgically treated many times. Magnetic resonance imaging revealed a large gas-containing abscess involving the base of the penis and the corpus cavernosum. The patient was brought to the operating room for total colectomy, end-ileostomy, incision and drainage of his perianal abscesses, and possible fistulotomy. Monitoring consisted of standard monitors as well as an arterial line, central venous line, and an esophageal temperature probe/stethoscope. Anesthesia was induced with 250 µg fentanyl and 100 mg propofol IV. Tracheal intubation was facilitated with 70 mg rocuronium IV. Anesthesia was maintained with 2.0%9.0% end-tidal desflurane in air/O2 (FIO2 = 0.5). The patient was placed in the lithotomy position, and a baseline blood gas analysis was performed. The abscess involved the right bulbospongiosus muscle and corpus cavernosum. Multiple draining fistulae were identified in the perineum. A total of 60 mL 3% H2O2 was injected by hand in aliquots from a single syringe over 1 min into several of these fistulae. The foaming was observed in an attempt to identify their internal openings. Within 30 s, there was a precipitous decrease in end-tidal carbon dioxide tension (PETCO2) from 32 to 13 mm Hg. His blood pressure decreased from 140/65 to 80/50 mm Hg, and the oxygen saturation (SpO2) decreased from 100% to 92%. His central venous pressure (CVP) increased from 8 to 22 mm Hg. A venous gas embolism (VGE) was suspected and the patient was immediately tilted 20° to the left. The FIO2 was increased to 1.0, and the central venous line was aspirated. No gas was returned from the catheter. Esophageal auscultation revealed a loud, harsh, systolic/diastolic heart murmur and normal breath sounds. His ventilatory variables remained unchanged. No resuscitative drugs were required to maintain hemodynamic stability. Blood gases were sent serially for analysis, and showed hypoxemia and hypercapnia (Table 1). These changes resolved fully within 32 min.
His vital signs returned to baseline within 15 min. The new murmur disappeared within two hours. The patient emerged from anesthesia uneventfully, was tracheally extubated, and had no neurologic deficits or further complications.
Ten mL of O2 are released from every mL of 3% H2O2, and 60 mL of H2O2 was injected; therefore a large amount of O2 could have embolized to the heart. The likely passage of the O2 was from the fistula tract to the corpus cavernosum, where it had access to a venous plexus and traveled to the right heart and the pulmonary circulation, resulting in the constellation of decreased PETCO2, systemic hypotension, increased CVP, and hypoxemia. The new murmur represented the classic "mill-wheel" murmur of VGE (14). A differential diagnosis for the observed physiologic derangements would include air embolism (from the opened abscess cavity that was exposed to the atmosphere) and thromboembolism. Spontaneous venous air embolism is unlikely in this situation because the operative site was below the level of the patients heart, the patients legs were elevated in the lithotomy position (increasing preload), and the patients CVP was 8 mm Hg. Thromboembolism is unlikely because of the rapidity with which the PETCO2, blood pressure, SpO2, and CVP returned to normal. In addition, the patient had perioperative protection against deep venous thrombosis with subcutaneous heparin. A thrombus large enough to cause the observed findings would not be expected to undergo endogenous fibrinolysis within 30 minutes and, if it continued to migrate forward within the pulmonary vasculature, it would be expected to cause continuing gas exchange abnormalities, which did not occur. We observed a large increase in calculated dead-space ventilation which normalized completely within 32 minutes (Table). Embolized gas tends to rise to nondependent regions of the lung, which limits pulmonary capillary perfusion and creates new regions of the lung with low perfusion but normal ventilation (15). New dead-space also results from the reduced cardiac output observed when the right ventricle (RV) fails because of the increased pulmonary vascular resistance seen as the pulmonary vasculature fills with gas (15). The treatment of oxygen embolism includes standard principles of management of gas embolism, reviewed recently (14). This includes repositioning the patient so that there is no atmospheric pressure gradient between the surgical site and the right atrium. In our patient, this concept was immaterial because the H2O2 was forcibly injected, eliminating the need for any pressure gradient. Traditionally, the left lateral, head down position has been recommended to "trap" gas bubbles in the RV and thereby prevent their passage into the RV outflow tract and to direct arterial bubbles away from the cerebral circulation (16). However, in animal studies, both of these tenets have been questioned, as different positions did not affect hemodynamics, time to recovery, cerebral gas embolic events, or survival (16,17). An echocardiographic study showed that, despite the presence of RV air, no RV outflow tract obstruction occurred in any position after VGE, and that positions other than supine could be detrimental (18). Systemic arterial gas embolism can result from VGE either by transpulmonary movement of gas bubbles (15) or via a patent foramen ovale (PFO), which is present in 20%34% of the population (19). PFO passage is facilitated when right atrial pressure exceeds left atrial pressure. As our patient had an acute increase in CVP, the transatrial passage of bubbles was a possibility. Transpulmonary movement of gas may be facilitated by volatile anesthetics (20). Arterial gas embolism can cause focal neurologic deficits or diffuse encephalopathic states (14), and if either is detected postoperatively the presumptive diagnosis should be paradoxical gas embolism. These patients should be treated in a hyperbaric facility (21) even if the diagnosis is delayed (22,23). Because the gas that embolized in our patient was O2, ventilating the lungs with 100% O2 might actually have slowed the rate of egress from the body, as one of the major factors for gas removal is the pulmonary capillary-alveolar gradient. Ventilation with 100% O2 decreases this gradient and retards removal. However, with an acute gas embolism, action must be taken quickly, and switching to 100% O2 is justifiable, especially because other routes of O2 removal, such as plasma dissolution and metabolism, probably work to remove O2 bubbles. In our patient, the gas exchange abnormalities and hemodynamic changes resolved quickly, making it unlikely that ventilating the lungs with 100% O2 impaired recovery to a significant extent. Conventional transanal ultrasound provides a correct assessment of fistula-in-ano in 62% of patients (5). H2O2-enhanced transanal ultrasound improves the accuracy to 95%, and is associated with a change in surgical management in 50% of cases (5). This diagnostic improvement is remarkable, but magnetic resonance imaging can attain similar accuracy with very minimal risk to the patient (6). We report the first case of venous oxygen embolism caused by the injection of H2O2 into a fistula to locate its internal origin. Morbidity and mortality produced by H2O2 has also occurred during colonic irrigation (7), lumbar discectomy (8), stereotactic brain biopsy (9), wound packing/irrigation (1012), and even after accidental ingestion (13). Several authors have recently advocated using H2O2 as a contrast agent for identifying fistula tracts ultrasonographically (5,6), which may increase the number of potentially life-threatening oxygen emboli that occur. Moreover, these emboli may happen in clinical areas without immediate access to resuscitative equipment and personnel, possibly reducing the chance of survival. We advise caution with the routine surgical usage of H2O2, especially near venous spaces.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|